Skip to content
how to activate JK BMS

How to Activate JK BMS: A Step-by-Step Guide

    If you’re using JK BMS for the first time, you probably already know that it needs to be activated before it can start working. But how can you activate it? In this article, we will show you how to activate JK BMS using different methods.

    Method 1: Using a 2-inch display

    JK BMS 2 inch display activate button
    JK BMS 2 inch display activate button

    If you have a 2-inch display for your BMS, you can use the button on the display to activate or deactivate the BMS. When the BMS is off, a short press on the button activates the BMS. When the BMS is active, press and hold the button for 5 seconds to deactivate the BMS.

    Here are the steps to activate JK BMS using a 2-inch display:

    • Connect the display to the LCD port on the BMS board using the provided cable.
    • Connect the battery pack to the B- port on the BMS board.
    • Connect the load or charger to the P- port on the BMS board.
    • Make sure that all connections are secure and correct.
    • Press the button on the display briefly to turn on the BMS. You should hear a beep sound and see some information on the display, such as battery voltage, current, temperature, etc.
    • To turn off the BMS, press and hold the button on the display for 5 seconds. You should hear another beep sound and see “OFF” on the display.

    Method 2: Using a manual push button switch

    Activate Button for JK BMS
    Activate Button for JK BMS

    If you have a manual push button switch for your BMS, you can connect it to the LCD pin 1 and 2 on the BMS board. Hold for 1 second and the BMS will switch on. If the button is held for 5 seconds, the BMS will switch off.

    Here are the steps to activate JK BMS using a manual push button switch:

    • Connect one end of the switch to the LCD pin 1 on the BMS board using a wire.
    • Connect the other end of the switch to the LCD pin 2 on the BMS board using another wire.
    • Connect the battery pack to the B- port on the BMS board.
    • Connect the load or charger to the P- port on the BMS board.
    • Make sure that all connections are secure and correct.
    • Press and hold the switch for 1 second to turn on the BMS. You should hear a beep sound from the BMS board.
    • To turn off the BMS, press and hold the switch for 5 seconds. You should hear another beep sound from the BMS board.

    Method 3: Using a 9-volt battery

    If you do not have a display or a switch for your BMS, you can use a 9-volt battery to activate the BMS. Connect the positive side of the 9-volt battery to the negative end of the cells, the B- lead of the BMS. Then connect the negative side of the 9-volt battery to the P- lead of the BMS. Just touching it for a fraction of a second should get you the beep from the BMS and it will turn on.

    Here are the steps to activate JK BMS using a 9-volt battery:

    • Connect the positive side of the 9-volt battery to a wire with an alligator clip or similar connector.
    • Connect the negative side of the 9-volt battery to another wire with an alligator clip or similar connector.
    • Connect the battery pack to the B- port on the BMS board.
    • Connect the load or charger to the P- port on the BMS board.
    • Make sure that all connections are secure and correct.
    • Connect the wire with the positive side of the 9-volt battery to the negative end of the cells, the B- lead of the BMS. 
    • Touch the wire with the negative side of the 9-volt battery to the P- lead of the BMS. You should hear a beep sound from the BMS board and see some LED lights on it.
    • Remove the wires from the 9-volt battery and the BMS board.

    Method 4: Using the diode test mode of a multimeter

    Multimeter Diode Test Mode
    Multimeter Diode Test Mode

    You can also use the multimeter’s diode test mode to activate the JK BMS.This is a very simple method, but it doesn’t work for every multimeter.

    • Switch the multimeter to diode test mode.
    • Connect the battery pack to the B-port of the JK BMS.
    • Connect the negative terminal of the load or charger to the P-port of the JK BMS.
    • Make sure all connections are correct and secure.
    • Touch the positive probe of the multimeter to the B-port of the JK BMS.
    • Touch the negative multimeter probe to the P-port of the JK BMS. You will get a beep and the JK BMS is activated.
    • Remove the multimeter probes.

    Here’s a video for this method.

    Conclusion

    In the above article we described 4 common ways to activate JK BMS. The most reliable method is to use a physical key to activate JK BMS as in methods 1 and 2.

    The good news is that energiepanda is offering all JK BMS for sale from September 2023 with a free activation button.


    Energiepanda can currently deliver JK BMS quickly to customers in North America, Europe, Australia, Asia and South Africa


    JK PB Series BMS Firmware Update & Upgrade Guide

    JK PB Series BMS Firmware Update & Upgrade Guide

    JK-PB Series BMS Firmware Update. Fix issues and improve communication with inverter. Download the l…

    MEAN WELL SBP-001 Intelligent Battery Charging Programmer Datasheet

    MEAN WELL SBP-001 Intelligent Battery Charging Programmer Datasheet Download

    MEAN WELL SBP-001 programmer lets you customize charging curves (CC/CV/FV/TC) for NPB-450/750/1200/1…

    MEAN WELL NPB-1700 Smart Battery Charger Datasheet Download 1

    MEAN WELL NPB-1700 Smart Battery Charger Datasheet Download

    MEAN WELL NPB-1700: 1700W high-power smart charger with auto voltage detection, ultra-wide 10.5–80V …

    MEAN WELL NPB-1200 Smart Battery Charger Datasheet Download

    MEAN WELL NPB-1200 Smart Battery Charger Datasheet Download

    MEAN WELL NPB-1200: 1200W ultra-compact smart charger with auto voltage detection, 10.5–80V ultra-wi…

    MEAN WELL NPB-750 Smart Battery Charger Datasheet

    MEAN WELL NPB-750 Smart Battery Charger Datasheet Download

    MEAN WELL NPB-750: 750W ultra-compact smart charger with auto voltage detection, 10.5–80V ultra-wide…

    MEAN WELL NPB-450 Smart Battery Charger Datasheet Download

    MEAN WELL NPB-450 Smart Battery Charger Datasheet Download

    MEAN WELL NPB-450: 450W ultra-compact smart charger with auto voltage detection, ultra-wide 10.5–100…

    Leave a Reply

    Your email address will not be published. Required fields are marked *